By Ericka Marsh


Everyone has a freezer -refrigerator in their homes as a means to keep food fresh or frozen until such a time that it is needed. Each of these appliances has a control that operates the cooling system, which is a system that allows the vents to be either opened or closed allowing more or less of the cold air to circulate. These do become faulty and many have had to have the temperature controls repair.

Before one is attempting to test or repair this issue, in Chicago, IL, they must first switch off the refrigerator by unplugging it at the wall. This might seem logic to many, but this step is the most forgettable one. Then proceed by removing the housing or the control dial and pull it away from the wall. Carefully remove the temperature control by either unscrewing the screws or by depressing the clips with a small screwdriver.

At ACT or Automation and Control Technologies one will be able to down load a book to a practical guide to maximizing a machine uptime for free. They offer quotes that are one hundred percent risk free and their turnabout times are very fast. Each of their repairs will be backed by a one year warranty for peace of mind.

If these need to be replaced check to see which kind they might be. The one slip-on connector could be soldered to the wire and the other crimped. The crimped on ones are much faster and easier but there is a possibility that they do not make a good connection or are loose. The soldered ones very seldom come loose but do require more time as a soldering iron is needed.

They are often used with metals such a platinum as they do not become affected with oxidation or corrosion. Other materials such as nickel-iron, alloy, copper and nickel are also used but not very often. They tend to have a lower temperature capability and do not remain stable unlike platinum.

They specialise in low level signal instrumentation as well as temperature instruments and only use the standards of NIST for guarantee and calibration. If the product cannot be repaired they will be able to give engineering assistance for those that wish it. Once the repairs are done they will be load tested and monitored for any irregular problems.

If it does not need to be replaces test for continuity with the use of a multi-tester. Set this to the ohms X1 setting and put each probe into a terminal. The reading should be at the end of the infinite scale. Change the controls to the coolest setting and retest. If the reading did not pass it could mean the switch should be replaced.

Reconnect the wires correctly and then snap the housing or re-screw in the screws back into place. Once this is completed it is now safe to switch the appliance back on. Everything should now be back to normal and working well for the next few years.




About the Author: